Facts
General description
Part number | 630000105 |
Life cycle status | Active |
Warranty | 2 year |
Certifications
General | CE, FCC, KCC |
Marine | KR, LR, ABS, BV, CCS, NK, DNV GL |
Safety | UL 61010-1, UL 61010-2-201, CAN/CSA-C22.2 No. 61010-1, CAN/CSA-C22.2 No. 61010-2-201 |
Mechanical
Mechanical size | 145 x 104 x 50mm |
Mounting option | Panel Mount, VESA 50 x 50 |
Number of touches | 1million finger touch operations |
Touch type | Resistive |
Cut-out size | 130 x 89mm |
Weight | 0.5 kg |
Housing material | Powder-coated aluminum, Gray |
Power
Input voltage | 24 V DC (18 to 32 VDC)CE: The power supply must conformwith the requirements according to IEC 60950 and IEC 61558-2-4.UL and cUL: The power supplymust conformwith the requirements for class II power supplies. |
Power consumption (max) | 12W |
Input fuse | Internal DC fuse |
System
Hardware platform | X2 |
CPU | i.MX6Solo Single Cortex-A9 1.0GHz 512kBL2cache |
RAM | 512 MB |
FLASH | 2GB SSD(eMMC), 1.5GB free for application |
Display
Size diagonal | 4.3″ diagonal |
Resolution | 480x272 pixels |
Backlight | LED Backlight |
Backlight life time | 50000 hours |
Backlight brightness | 300 cd/m2 |
Backlight dimming | Industrial Dimming |
Display type | TFT-LCD with LED backlight |
Serial communication
Number of serial ports | 1 Port 9pin DSUB |
Serial port 1 | RS 232 (RTS/CTS) |
Serial port 2 | RS422/485 |
Serial port 3 | RS485 (only if COM 2 is RS485) |
Ethernet communication
Number of Ethernet ports | 1 |
Ethernet port 1 | 1x10/100 Base-T (shielded RJ45) |
Expansion interface
Expansion port | Yes, ciX expansion module |
SD card | SD and SDHC |
USB | 1xUSB 2.0 500mA |
Environmental
Operating temperature | -10°C to +60°C |
Storage temperature | -20°C to +70°C |
Shock | 15g, half-sine, 11ms according to IEC60068-2-27 |
Vibration | 1g, according to IEC 60068-2-6, Test Fc |
Sealing front | IP66, NEMA 4X/ 12 and UL50E Type 4X/ 12 |
Sealing back | IP20 |
Humidity | 5% – 85% non-condensed |
Altitude (max) | < 3000m |
Resources
Knowledge
Program examples/Start-up
Product information
File name | Date | |
---|---|---|
Battery test summary - X2 pro, X2 control, X2 marine | 2022-09-22 15:39:23 | |
Release notes PIEN344D / Last minute notes PIEN345D | 2022-12-08 12:02:50 | |
X2 export control and dual use | 2023-02-08 14:48:11 | |
X2 image 1.0 b325 Last Minute Notes | 2022-09-22 15:33:40 | |
X2 Letter of Volatility | 2023-04-28 09:39:15 | |
X2 pro image 1.0 b325 Release Notes | 2022-09-22 15:33:40 | |
MTBF Summary X2 pro, X2 control, X2 motion, X2 marine | 2025-01-08 11:24:47 |
Certificates
Drawings
Manuals
File name | Date | |
---|---|---|
Best Practice Image Update X2 HMI Panels 2.2, MAEN361 rev. B | 2023-06-14 11:53:55 | |
Installation manual for X2 pro 4 - B2, MAEN350 English | 2023-01-30 11:31:46 | |
iX Developer manual - online | ||
iX Developer Reference Manual, MAEN355 rev. B (current version) | 2023-09-19 14:12:01 | |
X2 base / pro / extreme / marine / control - Configuration and Image manual , MAEN352 rev B | 2024-05-07 13:28:37 | |
X2 pro 4 manual - online | ||
Installation Manual X2 pro, X2 marine, X2 control MAxx202 | 2023-01-30 12:05:27 |
Information document
Software
File name | Date | |
---|---|---|
FTDI Direct driver demo | 2022-09-22 15:37:27 | |
Melsec Q Profibus DB development kit | 2022-09-22 15:40:34 | |
Remote Access Viewer v1.5.4, for Exter/E1000 - TxA/TxB/TAxx - X2 panels | 2023-08-28 08:26:38 | |
SqlProxy - Connects iX Panels transparently to SQL Server | 2023-06-07 16:02:43 |
Configuration files
File name | Date | |
---|---|---|
EDS file for CiX-CAN and X2 | 2022-09-28 13:38:21 | |
GSD files for CiX-DP Profibus module | 2022-10-10 08:34:45 |
Brochures
File name | Date | |
---|---|---|
X2 brochure (English), BREN631 | 2022-09-21 08:11:56 | |
X2 brochure (Spanish) | 2022-09-21 08:12:32 | |
X2 brochure 2019 (French) | 2024-01-15 10:52:15 | |
X2 series (German) | 2022-09-21 08:11:38 |
System program
File name | Date | |
---|---|---|
X2 image 1.0 b325 | 2022-09-22 15:33:33 | |
X2 image 1.1 b448 release | 2022-09-22 15:34:05 | |
X2 pro - X2 control - Image V1.3b569 (Obsolete) | 2022-09-22 15:34:26 | |
X2 pro / marine / BoX2 pro image V2.2 b1041 | 2024-05-21 11:20:58 | |
X2 pro / X2 marine / BoX2 pro image V1.5 (Obsolete) | 2022-09-22 15:36:50 | |
X2 pro / X2 marine / BoX2 pro image V2.1 HF b909 | 2023-08-25 08:06:29 | |
X2 pro / X2 marine / BoX2 pro, image V2.0 b773 (Obsolete) | 2022-09-22 15:39:01 | |
X2 pro / X2 marine / X2 control - Image V1.4 b581 (Obsolete) | 2022-09-22 15:36:09 |
Smart Engineering Resources
IX otf and ttf fonts
23.11.2022
IX developer 2.40Sp7
X2 terminals (actually windows CE \ wec2013 ), do not support the newer OTF font standard ( OpenType Font) . Only TTF ( true type font) are supported for terminal targets, however on a PC RT ( Run Time ) you can use OTF.
It is possible to convert a OFT font to TTF: https://cloudconvert.com/otf-to-ttf
iX Developer SP7 - 2.47.473 Release information
Driver MODICON Modbus Slave: Command XDNCW
Creating a custom Welcome screen / Startup screen on a X2 operator panel
X2 series
It's possible to create a custom Welcome Screen / startup screen, this is described in detail in the Configuation and Image manual:
X2 Configuration and Image manual
iX - SMTP - Using Gmail servers using App password
Google has dropped the support for "less secure apps" and no longer supports the use of third-party apps or devices which ask you to sign in to your Google Account using only your username and password.
From now on an "App Password" is required when sending emails from iX panels that are configured to use Gmail's SMTP servers. Please notice that 2 step verification is required in order to create an app password.
Create and use App Password
- Login to you Google account.
- Make sure 2-Step Verification is enabled.
- Generate an App password. Select "Mail" as app and for device select "Other" and enter a custom name. Click Generate to get an app password.
- Then use the following settings for the email device in the iX application
From Email Address: [Gmail address]
SMTP Server: smtp.gmail.com
Port: 587
Encryption Mode: ExplicitSSL
Authentication Mode: AuthLogin
Username: [Gmail address]
Password: [The App Password]
X2 enter service menu with an USB mouse
13.02.2025
X2 series b1103
You can enter the service menu with the USB mouse like this:
- Reboot
- Hourglas shows for a while
- Hourglas go away.
- Screen is black
- Hourglas is back again
- NOW press and hold the left mouse
- When touchcalibrat screen appears, release and click to enter the service menu.
How to download Free software packages from SmartStore
This document provides guidelines for customers when downloading free software and firmware packages from SmartStore. The following chapter describes the procedures of:
ARTI - 8bit data types not working
ARTI driver 4.16.05
Normally the use of 8bit data types is supported if the option "Load symbols when connecting" = TRUE.
With version 4.16.05 the driver will constantly report "Datatype mismatch" if any kind of 8bit datatype, defined in the controller, is in use.
Workaround:
- Use the previous driver 4.15.04
- Change the datatype in the controller to 16bit
Extract from driver help.
OPC ua settings in Phoenix plxnext engineer
04 october 2022
To use IX OPC client with Phoenix PLC's some settings are needed in the PLxnext engineering tool, and also the PLC Webserver:
Basic settings "Visibility of variables" = "Marked"
Subject1 = HMI ip adress
UNcheck "Use the thruststore for client authentication" AND " Check application URI against client certificate.
To get the NS ( namespace ) settings in IX developer correctly, the easiest way is to browse the Phoenix server from IX developer, by clicking the small down arrow at the right side of the "ADD" button in Tags, and select "Add tags from OPC server" . Then the nemespaces are set automaticly. Otherwise you can see them in the screenshot below:
WEB Server:
Disable Autentication in WBM in the PLC
Login with "admin" and the password on the plc lable
Image Sticking
When utilizing TFT LCD HMI panels in applications where a fixed or partially fixed image remains displayed on the screen for extended periods of time, users may experience a phenomenon referred to by the LCD industry as Image Sticking. Image Sticking - sometimes also called "image retention" or "ghosting"- is a phenomenon where a faint outline of a previously displayed image remains visible on the screen when the image is changed.
Image sticking can be caused by:
- Static images
- No Screensaver
- Sharp contrast transition (e.g. black / white)
- High ambient temperatures
- Use the screensaver functionality.
- Changing constantly between static and dynamic images
- Avoid excessive brightness differences between foreground and background elements
- Use colors with similar brightness
- Use complementary colors in follow-up images
X2 platform usb mouse if damaged touch
20.11.2024
X2 platform in general
(tested on Marine and pro)
On The E1000 and txA / txB platforms one could, in cases of damaged touch surface, disconnect the touch foil cable from the mainboard and emergency operate the unit with an USB mouse. With the X2 platform however, when disconnecting the touch foil cable, the USB mouse are not able to override the same way. The pointer is stuck in the upper right corner (actually it is invissible until you move the mouse quite hard).
The only workaround left, is remote control via VNC. This stil works, but requires ofcours a computer with a vnc client installed, and that the remote access feature is enabled in the project. 😥
Best Practice Database on SD card or flash memory
This document provides recommendations for how to setup and use the X2 HMI panel in the best way to reduce unnecessary wear on the flash memory.
For more information: Best Practice Image update for X2 pro, X2 marine and BoX2 pro 2.1 HF
Quick start guide, Disable / Suppress Flashwear warning dialogue on X2 series SUEN00411
30.01.2023
X2 series
This Document describe how to enter the service menu, go to settings in the diagnostics part, and supress the flash wear warning message.
Max number of recipe items / tags
iX developer 2.40 SP7
The help file states that maximum 256 recipe items can be used. This is wrong, maximum number of recipe items / tags / columns is 998.
When attemting to add more, iX will display a popup with an error message.
Convert from Exter/E1000 To X2 Series
The Mitsubishi E-Series hardware products and E-Designer software have been manufactured by Beijer Electronics for Mitsibishi for many years. In 2015, this partnership ended. Beijer-branded E1000 HMIs are now orderable directly through Beijer or one of its authorizated distributors. As your Mitsubishi terminals need to be replaced, Beijer provides a smooth transition by offering three paths:
Direct Replacement Path (E1000 panels) - A direct hardware and software replacement for most E1000 panels. The Beijer-branded E1000 panels are identical to the Mitsubishi-branded E1000 panels, only the rear labeling is different.
Direct Replacement Path (EXTER panels) - A direct mechanical drop-in hardware replacement is available for most E1000 products. The replacement products use your existing E-Designer applications after a simple project conversion to Information Designersoftware, a service offered by Beijer Technical Support
Upgrade Replacement Path (X2 panels) - Enhance your future HMI offering with modern X2 hardware and state-of-the-art iX Developer software including graphics, scripting, alarms, recipes, remote access and multiple communication drivers. iX Developer supports and integrated E-Designer to iX Developer project conversion feature (as well as Information Designer to iX Developer).
The following is a comparison chart of the older, discontinued E-series/CIMREX HMI panels to the current E1000/EXTER HMI panels, as well as the closest versions to Beijer''s latest X2 panels.
Discontinued | Discontinued | Current | Current | Adapter | Current |
E-Series Models1 | CIMREX Models2 | E-1000 Models3 | EXTER Models4 | Plate5 | X2 Models6 |
E50 | CIMREX 5 | n/a | n/a | n/a | n/a |
E100 | CIMREX 10 | E1012 | K10m | n/a | X2 base 5 |
| | | | | X2 pro 4 |
E150 | CIMREX 12 | E1012 | K10m | n/a | X2 base 5 |
| | | | | X2 pro 4 |
E200 | CIMREX 20 | E1022 | K20m | Adaption Plate K20 | X2 base 5 |
| | | | | X2 pro 4 |
E300 | CIMREX 30 | E1032 | K30m | Adaption Plate K30 | X2 base 5 |
| | | | | X2 pro 4 |
E410 | CIMREX 41 | E1043 (mono) | T40m5 (EOL) | n/a | X2 base 5 |
| | E1041(color) | T405 (EOL) | | X2 pro 4 |
E600 | CIMREX 60 | E1060 (color) | K60m | Adaption Plate K60 | X2 base 7 |
| | E1062 (mono) | | | X2 pro 7 |
E610 | CIMREX 67 | E1063 | T60m5 (EOL) | Adaption Plate T60 | X2 base 7 |
| | | | | X2 pro 7 |
E615 | CIMREX 69 | E1061 | T605 (EOL) | Adaption Plate T60 | X2 base 7 |
| | | | | X2 pro 7 |
E615T | CIMREX 69T | E1061 | T605 (EOL) | Adaption Plate T60 | X2 base 7 |
| | | | | X2 pro 7 |
E700 | CIMREX 70 | E1070 | K60 or K70 | Adaption Plate K70 | X2 base 7 |
| | | | | X2 pro 7 |
E710 | CIMREX 71 | E1071 | T70 | Adaption Plate K70 | X2 base 7 |
| | | | | X2 pro 7 |
E900T | CIMREX 90 | E1100 | K100 | Adaption Plate K100 | X2 base 10 |
| | | | | X2 pro 10 |
| | | | | X2 pro 12 |
E900TD | CIMREX 90D | E1100 | K100 | Adaption Plate K100 | X2 base 10 |
| | | | | X2 pro 10 |
| | | | | X2 pro 12 |
E900VT | n/a | E1100 | K100 | n/a | X2 base 10 |
| | | | | X2 pro 10 |
| | | | | X2 pro 12 |
E910T | CIMREX 91 | E1101 | T100 | Adaption Plate T100 | X2 base 10 |
| | | | | X2 pro 10 |
| | | | | X2 pro 12 |
E910TD | CIMREX 91D | E1101 | T100 | Adaption Plate T100 | X2 base 10 |
| | | | | X2 pro 10 |
| | | | | X2 pro 12 |
n/a | n/a | E1151 | T150 | n/a | X2 pro 15 |
1 The Beijer-built E-series models were branded for Mitsubishi. The CIMREX models were the Beijer-branded versions of the early E-series models. All were discontinued a number of years ago.
2 The E1000 models are upgrades from the older, discontinued E-series models. Historically, the Beijer-built E1000 models were branded for Mitsubishi, but now carry a Beijer brand. The E1000 are now only available from Beijer or an authorized distributor; they are no longer available from Mitsubishi. E1000 programming is based on E-Designer software which can now only be obtained from Beijer.
3 The Beijer-built and branded EXTER models are virtually identical to the E1000 models. EXTER programming is based on Information Designer software. Beijer Technical Support can convert an E-Designer program to an Information Designer program, if required.
4 X2 models are not 100% replacement models for the E1000 or EXTER models. They have different form-factors; there are no X2 Keypad models; all X2 models have color displays. These X2 models are the closest versions to the E1000/EXTER panels. X2 pro models have more memory and faster processors than the X2 base units. iX Developer can import an E-Designer or Information Designer project to run on X2 models, though it may not import 100% of the functionality.
5 Adapter plates enable a smaller footprint EXTER or E1000 HMI to fit in the space occupied by a slightly larger, discontinued Exxx or CIMREX model. Note: Adapter Plates allow most E1000/EXTER models to fit the cut-outs used by the discontinued E-series/CIMREX models.
6 X2 series are Beijer main iX models. See the EOL Notifications for details.
X2 BatteryCheck
28.05.2024
X2 \ IX 2.50
There is a feature in the BeHwApi that gives the status of the battery. Specially convenient for Box2 since they have no screen.
This feature was implementet aprox. from b906 of the firmware so an update can be needed if implementing in older terminals.
Sample code for a tagscript that use the SystemTagMinutes to set\reset a global tag according to the battery status: (see also attached X2 Control 10 project)
X2 image - Update EBOOT require SD card to be formatted to FAT16/FAT32
Some versions of the system program to X2 require the EBOOT to be updated as well. The EBOOT is included when you create "Recovery SD" from the Image Loader. Please note that the SD card must be formatted to FAT16/FAT32 otherwise the EBOOT will not be updated even though the "Make Recovery SD Card" setting was enabled.
The file system exFAT is not supported when upgrading the EBOOT.
The EBOOT version can be verified in the diagnostics which can be opened from the service menu.
Best Practice Image update for X2 pro, X2 marine and BoX2 pro 2.1 HF, MAEN361
General information of image update procedure, service warnings and how to reduce flash wear on the HMI by storing data on SD cards
For more information: Best Practice Database on SD card or flash memory
X2 control/pro CAN bus limitations (HW rev. 1)
For utilization of CANopen or FreeCAN on X2 control, we recommend not to operate above 500 kBit/s, on point-to-point connections. For CAN bus network connections, with mutliple nodes, it is recommended to not run above 125 kBit/s.
In the current hardware revision, rev. 1, of X2 pro/control, the input filter on the COM connector has a high load capacitance. This may impact on termination, reflections and bit times, especially at high bit rates.
The high load capacitance will be corrected in hardware revision 2.
X2 pro / X2 marine / BoX2 pro image V2.1 HF b909
Firmware image for X2 pro, X2 marine and BoX2 pro.
Viewing angle X2 series
Beijer | Viewing angle horizonal typ. | Viewing angle vertical typ. |
X2 base 5 v2 | 70/70 | 50/70 |
X2 base 7 v2 (HP) | 80/80 | 60/70 |
X2 base 10 v2 (HP) | 75/75 | 60/60 |
X2 base 15 v2 (HP) | 80/80 | 80/80 |
X2 pro 4 | 80/80 | 80/80 |
X2pro7 | 70/70 | 60/70 |
X2pro10 | 80/80 | 60/80 |
X2pro12 | 80/80 | 65/80 |
X2pro15 | 80/80 | 70/70 |
X2pro21 | 89/89 | 89/89 |
X2marine7 | 70/70 | 60/60 |
X2marine7 HB | 70/70 | 60/60 |
X2marine15 | 80/80 | 70/70 |
X2extreme 7 | 70/70 | 60/60 |
X2extreme 7 HP | 70/70 | 60/60 |
X2 extrem 7 SL HP | 70/70 | 60/60 |
X2extreme 12 | 89/89 | 89/89 |
X2extreme 12 HP | 89/89 | 89/89 |
X2 extreme 12 SL HP | 89/89 | 89/89 |
X2extreme 15 | 80/80 | 70/70 |
X2extreme 15 HP | 80/80 | 70/70 |
X2 extreme 15 SL HP | 80/80 | 70/70 |
X2 Date time picker script
02.02.2023
X2 series.
This sample project let the user select a date and time from a calendar type of object and stores\presents the selected date/time in various formats in Global tags.
Add Tags to Tagmonitor by script
25.03.2019
IX dev. 2.40SP1
X2 control 10 (Should work on all platforms)
Attached sample project adds predefined tags to the TagMonitor object, making it easy to switch between several different sets of tags in the list
IX alarm info request lookup in pdf by page index
31.08.2021
IX developer 2.40 SP6
Demo driver
Consept:
This sample project uses An alarms uniq ID to produce an index.
This index is used to show aditional info from a PDF document, regarding the selected alarm, when the user click the Info button.
Details:
The Main script is in the alarmserver, and fires with the "AlarmServer_AlarmEventInfoRequested" event.
The index is made from the the alarm name column (first column in the alarm configurator that normally has no function for us ), which has default values: AlarmItem0, AlarmItem1 etc.
The script extract the number part 0,1,2 etc to a global tag, to be used as a page index in the PDF viewer object. Finally the Popup screen is opened.
In the popup screen The Pdf is opened, using the Alarm Taxt as Title, and the page corresponding to the index is shown.
PS.
If several alarm groups are in use, Each group will default start with the name AlarmItem0. This will make duplicates. So in this case you must manually verify that the number part in the names are uniq, and consistent.
Program example iX Developer: Modbus TCP communication between any X2 and BFI-P2/H3.
This is to be found in Smart Engineering, SER0050. Either download the manual further down for SER0050 or the complete Smart Enginnering here.
Program example support:
- Works only towards BFI Frequency inverters BFI-H3 and BFI-P2
- Start and stop
- Change Setfrequency
- Normal-, fast- or coasting-stop
- Inverter Alarm Reset
- Constant overview of Drive Outputs-, Alarm-, Safety-, Running Hours status
- Read and Write of all parameters and data available in the inverter
- Read of Drive type, Input voltage, Power, Frame size, Firmware and serialnumber
- Trend
HMI project created in iX Developer 2.40 SP6.
Program example iX Developer: Modbus RTU communication between any X2 and BFI-E3, BFI-P2 or BFI-H3.
This is to be found in Smart Engineering, SER0051. Either download the manual further down for SER0051 or the complete Smart Enginnering here.
Program example support:
- Works only towards BFI Frequency inverters BFI-E3, BFI-H3 or BFI-P2
- Start and stop
- Change Setfrequency
- Normal-, fast- or coasting-stop
- Inverter Alarm Reset
- Constant overview of Drive Outputs-, Alarm-, Safety-, Running Hours status
- Read and Write of all parameters and data available in the inverter
- Read of Drive type, Input voltage, Power, Frame size, Firmware and serialnumber
- Trend
HMI project created in iX Developer 2.40 SP6.
Program example iX Developer: Modbus TCP communication between any X2 HMI and BFI-E3.
This is to be found in Smart Engineering, SER0060. Either download the manual further down for SER0060 or the complete Smart Enginnering here.
Example shows how X2 Base7 control/monitor up to 63 BFI-E3 in a Modbus TCT network. Functions supported are:
Program example support:
- Works only towards BFI Frequency inverter BFI-E3-MTP
- Start and stop
- Change Setfrequency
- Normal-, fast- or coasting-stop
- Inverter Alarm Reset
- Constant overview of Drive Outputs-, Alarm-, Safety-, Running Hours status
- Read and Write of all parameters and data available in the inverter
- Read of Drive type, Input voltage, Power, Frame size, Firmware and serialnumber
- Trend
HMI project created in iX Developer 2.40 SP6.
iX Templates for E-key and X-Key
Templates for E-key and X-key, created as popups.
Unzip the *.zip file in < C:\Users\Public\Documents\Beijer Electronics AB\iX Developer 2.40 SP4\Screen Templates > and the templates will be available under “Add Screen”>Templates
Connect an action to the buttons, LED-colourfärg/Led-blink as dynamic if used.
Quick start guide - Connect X2 HMI with Nexto PLC, SUEN00414
Ping from IX x2 terminal
27.02.02
IX dev. 2.40 SP4
The attached project sample (X2 control 10), Pings a fixt IP adress every 30 sec, and set\rst a global tag accordingly, to show the status of the connection.
All code is in a scriptmodule, initiated by the "created" event.
The actual Ping syntax is: (returns true\false)
if(Core.Api.Service.ServiceContainerCF.GetService<Neo.ApplicationFramework.Interfaces.INetworkService>().Ping("10.0.0.1", 100))
iX Developer - Top10 Alarm list, based on count and/or duration
You easily implement a Top10 Alarm list in iX.
1. Add a DatabaseViewer control to a screen
2. Add the following script to the screen:
void AlarmScreen_Opened(System.Object sender, System.EventArgs e)
{
DatabaseViewer1.IsControlVisible = false; //Optional, to hide manual controls
}
void btnTop10_Click(System.Object sender, System.EventArgs e){
string sFrom = "1900-01-01"; string sTo = "2999-12-31";
DatabaseViewer1.SendSelectQuery("SELECT [AlarmItemName], [Text], AlarmItemDisplayName,COUNT(*) AS [Count],SUM(strftime('%s',InActiveTime) - strftime('%s',ActiveTime)) AS [Duration (s)] FROM AlarmServer WHERE ActiveTime >= '" + sFrom + "' AND ActiveTime <= '" + sTo + "' GROUP BY [AlarmItemName],AlarmItemDisplayName,[Text] ORDER BY COUNT(*) DESC,[Duration (s)] DESC","Database.db");
}
void btnTop10Duration_Click(System.Object sender, System.EventArgs e){
string sFrom = "1900-01-01"; string sTo = "2999-12-31";
DatabaseViewer1.SendSelectQuery("SELECT [AlarmItemName], [Text], AlarmItemDisplayName,COUNT(*) AS [Count],SUM(strftime('%s',InActiveTime) - strftime('%s',ActiveTime)) AS [Duration (s)] FROM AlarmServer WHERE ActiveTime >= '" + sFrom + "' AND ActiveTime <= '" + sTo + "' GROUP BY [AlarmItemName],AlarmItemDisplayName,[Text] ORDER BY [Duration (s)] DESC, COUNT(*) DESC","Database.db");
}
IX internal CanOpen driver as master against XP325 as CanOpen Slave
Example of IX internal CanOpen driver as master against XP325 as CanOpen Slave.
Quick Start Guide, MELSEC Qnn QJ71E71 Ethernet to X2 series SUEN405
Communication driver in X2: MC Protocol
Quick Start Guide, MELSEC iQ-R Ethernet - X2 series SUEN00406
Communication driver X2: MC Protocol
Quick Start Guide, MELSEC QnUDE Ethernet to X2 series, SUEN00403
Communication driver X2: MC Protocol
Quick Start Guide, MELSEC FX5U/FX5UC Ethernet to X2 series, SUEN00402
X2 Letter of Volatility
X2 Letter of Volatility
X2 base, X2 pro, X2 marine, X2 control, X2 motion
MTBF Summary X2 pro, X2 control, X2 motion, X2 marine
MTBF Summary X2 pro, X2 control, X2 motion, X2 marine
X2 pro image 1.0 b325 Release Notes
X2 image pro 1.0 b325 Release Notesv
Release notes PIEN344D / Last minute notes PIEN345D
Release notes for software image X2 v1.4 B581 (June 2018).
Supporting all model types of X2 pro / X2 marine / X2 control.
Click here to download the Image V1.4 b581.
Note! This image is obsolete, use latest version.
X2 image 1.0 b325 Last Minute Notes
X2 image 1.0 b325 Last Minute Notes
SDoC Green Passport
SDoC Green Passport
X2 pro, X2 control, X2 motion, X2 marine
RoHS and REACH Declaration of Conformity
Environmental Impact Report X2 pro, X2 marine, X2 control, X2 motion
Environmental Impact Report X2 pro, X2 marine, X2 control, X2 motion
ABS PDA certification X2 pro, marine, control, motion
X2 pro, marine, control, motion ABS PDA certification
DoC Green Passport Declaration
DoC Green Passport Declaration
X2 pro, X2 control, X2 motion, X2 marine
DoC CE, EMC, RoHS Declaration of conformity X2 pro, X2 control, X2 marine , X2 web, Box 2 pro
DoC CE, EMC, RoHS Declaration of conformity
X2 pro, X2 control, X2 marine, X2 web, Box2 pro
LR Type approval certificate X2 pro, X2 marine, X2 control, X2 motion
X2 LR Type approval certificate C1760002
X2 pro, X2 marine, X2 control, X2 motion
NOTE! not valid for X2 pro 21
Compass safe distance X2 pro/control/motion/marine
Compass safe distance X2 pro/control/motion/marine
CE Verification X2 pro
CE Verification X2 pro
X2 pro 4, X2 pro 7, X2 pro 10, X2 pro 12, X2 pro 15, X2 pro 21
- T210625D04-E_X2 pro 7 - B2_EMC Verification.pdf
- TMXD2108000175DE_X2 pro 10 – B2_EMC Verification.pdf
- TMXD2112001853DE_X2 pro 12 - B2_EMC Verification.pdf
- TMXD2112001858DE_X2 pro 4 - B2_EMC Verification.pdf
- TMXD2112001859DE_X2 pro 21 - B2_EMC Verification.pdf
- TMXD2201000407DE_X2 pro 15 - B2_EMC Verification.pdf
Manufacturer declaration: X2 pro marine control UKCA Declaration of Conformity
Manufacturer declaration: X2 pro marine control UKCA Declaration of Conformity
FCC Verification X2 pro
FCC Verification X2 pro
X2 pro 4, X2 pro 7, X2 pro 10, X2 pro 12, X2 pro 15, X2 pro 21
BV Type approval certificate X2 pro, X2 marine, X2 control, X2 motion
X2 pro, marine, control, motion BV Type approval certificate
Certificate number: 47303/B0 BV
X2 pro, X2 marine, X2 control, X2 motion
NOTE! not valid for X2 pro 21
CCS Marine Certificate X2 extreme, pro, control, marine
CCS Marine Certificate X2 extreme, pro, control, marine
KR certification X2 pro, X2 marine, X2 control, X2 motion
KR certification X2 pro, X2 marine, X2 control, X2 motion
Not valid for X2 pro 21
NKK certificate X2 pro, X2 marine, X2 control, X2 motion
NKK certificate X2 pro, X2 marine, X2 control, X2 motion No.TA17170M (PROD CERT - 1231856 - 1 - A1) - 1
X2 pro, X2 marine, X2 control, X2 motion
NOTE! not valid for X2 pro 21
ABS Type certification X2 pro, X2 marine, X2 control
X2 ABS Type approval certificate 16-SQ1516745-PDA
X2 pro, X2 marine, X2 control
NOTE! not valid for X2 pro 21
DNV certification X2 pro, X2 marine, X2 control
DNV certification X2 pro, X2 marine, X2 control
Not available for X2 pro 21
KCC, MSIP Certificate, X2 pro 4
KCC, MSIP Certificate, X2 pro 4
CAB108 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C iX operator panel
CAB108 Gender changer. 9pin Dsub male/male
CAB105 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
Cable between Allen Bradley Micrologix and X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C
Cable length: 3 meters.
CAB106 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
Cable between OMRON Host Link and X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C
Cable length: 3 meters.
CAB107, 25-pol to 9-pol adapter, Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, iX Panel TxA/B/C operator panel
CAB107 9pin Dsub to 25pin Dsub, for using EXTER/E1000 422/485 cables on X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C
Cable length: 0,2 meters.
CAB110 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
CAB110 Cable for MELSEC Q Transparent mode for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C
CAB109 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C iX operator panel
CAB109 Y-split cable to utilize more than two COM ports on X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C
Cable length: 2 x 0,1 meters.
CAB153 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
RS422 panel side termination plug
Used when RS422 point to point
communication is used
100-0549 |
CAB150 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, iX Panel TxA/B/C operator panel
3 way splitter cable
Used when 2xRS485 are needed
100-0526 |
CAB104 Cable Drawing forX2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
Cable between PC standard RS232 and X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C
Cable length: 3 meters.
CAB103 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C
Cable between MELSEC FX1/2/3-series and X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C
Cable length: 3 meters in drawing CAB103_3m.pdf.
Cable length: 10 meters in drawing CAB103_10m.pdf.
Cable length: 15 meters in drawing CAB103_15.pdf.
CAB101 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
CAB101 Cable between MELSEC Q and X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C
Cable length: 3 meters.
CAB100 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
Cable between GE Fanuc and X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C
Cable length: 3 meters.
Outline drawing, X2 pro 4, X2 control 4, X2 motion 4
Outline drawing, X2 pro 4, X2 control 4, X2 motion 4
Cutout drawing, X2 pro 4, X2 control 4, X2 motion 4
Cutout drawing, X2 pro 4, X2 control 4, X2 motion 4
3D drawing, X2 pro 4, X2 control 4, X2 motion 4 in STEP format
3D drawing, X2 pro 4, X2 control 4, X2 motion 4 in STEP format
iX Developer Reference Manual, MAEN355 rev. B (current version)
X2 base / pro / extreme / marine / control - Configuration and Image manual , MAEN352 rev B
MAEN352B: describes the X2 series system program V2.2 and later .
This manual replaces MAEN205 rev. G
Best Practice Image Update X2 HMI Panels 2.2, MAEN361 rev. B
Installation Manual X2 pro, X2 marine, X2 control MAxx202
Installation Manual X2 pro, X2 marine, X2 control
- Chinese Simplified
- Chinese Traditional
- English
- French
- German
- Italian
- Portuguese Brazil
- Spanish
- Installation Manual X2 pro, X2 marine, X2 control, X2 motion MABP202 Chinese Simplified.pdf
- Installation Manual X2 pro, X2 marine, X2 control, X2 motion MABP202 Chinese Traditional.pdf
- Installation Manual X2 pro, X2 marine, X2 control, X2 motion MABP202 French.pdf
- Installation Manual X2 pro, X2 marine, X2 control, X2 motion MABP202 German.pdf
- Installation Manual X2 pro, X2 marine, X2 control, X2 motion MABP202 Italian.pdf
- Installation Manual X2 pro, X2 marine, X2 control, X2 motion MABP202 Portuguese Brazil.pdf
- Installation Manual X2 pro, X2 marine, X2 control, X2 motion MABP202 Spanish.pdf
Guidelines for TxA and TxB migration to X2.
Guidelines for TxA and TxB migration to X2.
SqlProxy - Connects iX Panels transparently to SQL Server
There's sometimes a need to connect to SQL Server from an iX Panel.
In CE6 based panel, this has been possible using sqlclient.
Nothing similar is however supported in CE8 (most X2 panels).
During the years, we have helped customers creating solutions based on SQL Server connectivity.
There is a need to be able to move such an application to X2 aswell with minimal change of script code.
One solution is "SqlProxy" that is presented in the attached pdf file.
Download:
https://www.beijerelectronics.com/en/support/Help___online?code=4D4C0877-4291-43C8-BA7B-54A456B0B5FE
Install in e.g. C:\Users\Public\SqlProxy to avoid access right issues!
October 16, 2019: The file SqlProxy_191016C.zip contains CURRENT VERSION !
SqlProxy 1.1.0.1. Make sure to use corresponding SqlProxy.exe , tcpServer.dll and scmSqlProxy.Script.cs from the same package!
Supports unicode (e.g. Chinese characters and queries like select * from Customers where Name = N'公司黄页' ). Performance improved.
For best performance, limit the amount of data (number of rows and number of columns) to the minimum necessary with your SQL query. Example: "select top (1) createdTime, columnName3, columnName149 from tableName where columnName1 = 'something' order by createdTime desc"
to get just the few interesting columns from the very latest record where columnName1 = 'something'
Furthermore, for best performance, use StringBuilder when receiving reply from SqlProxy instead of += in the iX demo project. scmSqlProxy.Script_StringBuilder.zip in demo project contains this alternate scmProxy.Script.cs file if needed.
Contact support @beijer.se for additional info!
Remote Access Viewer v1.5.4, for Exter/E1000 - TxA/TxB/TAxx - X2 panels
Remote Access Viewer is a program for remote access and control Exter/E1000 - TxA/TxB/TAxx - X2 panels.
It is possible to access, reflect and control panels
from a PC by using the VNC client program, Remote Access Viewer (freeware),
together with the built-in VNC server (Remote Access function) in the iX
Panels.
NB: Even though the help file suggests another key combination, please note that Ctrl-Alt-Shift-F toggles Full screen mode on / off best, so you Restore from Fullscreen mode with this key combination!
vncviewer.exe_patch.zip contains a patched vncviewer.exe
Melsec Q Profibus DB development kit
This package contains:
FTDI Direct driver demo
This demo covers the utilization of the FTDI direct driver.
EDS file for CiX-CAN and X2
EDS_CiX-CAN.zip includes EDS files for the CiX-CAN module:
CiXCANopen.eds General EDS file
CiXCANopen_Default_PDO1.eds EDS file corresponding to Default Slave PDO setting 1
CiXCANopen_Default_PDO2.eds EDS file corresponding to Default Slave PDO setting 2
CiXCANopen_Default_PDO3.eds EDS file corresponding to Default Slave PDO setting 3
CiXCANopen_Default_PDO4.eds EDS file corresponding to Default Slave PDO setting 4
EDS_X2.zip includes EDS files for the internal CAN on X2 (extreme) panels:
X2CANopen.eds General EDS file
X2CANopen_Default_PDO1.eds EDS file corresponding to Default Slave PDO setting 1
X2CANopen_Default_PDO2.eds EDS file corresponding to Default Slave PDO setting 2
X2CANopen_Default_PDO3.eds EDS file corresponding to Default Slave PDO setting 3
X2CANopen_Default_PDO4.eds EDS file corresponding to Default Slave PDO setting 4
GSD files for CiX-DP Profibus module
X2 series (German)
36-page brochure incl. general and product family descriptions, technical data, iX and WARP software descriptions, migration paths, etc.
X2 brochure (English), BREN631
36 page brochure incl. general and product family descriptions, technical data, iX and acirr+ software descriptions, migration paths, etc. Incl. X2 extreme, X2 pro21 and two-year warranty
X2 pro / marine / BoX2 pro image V2.2 b1041
*All firmware files will be moved to smart store. Please follow this link to download this version:
https://smartstore.beijerelectronics.com/en/Firmware/15045/x2-pro-ver-2-2-b1041
Related documents:
X2 pro / X2 marine / BoX2 pro image V2.1 HF b909
Check on SmartStore for latest image version!
Unfortunately, this Sharepoint/HelpOnline entry is broken. Use this one instead:
X2 pro / X2 marine / BoX2 pro image V2.1 HF b909
https://www.beijerelectronics.com/en/support/Help___online?code=C8EE4A0E-1744-4454-BAB8-23B0F80400A4
Firmware image for X2 pro, X2 marine and BoX2 pro.
X2 pro - X2 control - Image V1.3b569 (Obsolete)
X2 image v1.3 Build569
Support of new X2 pro 7 – 2eth model, improvements and bug correction.
Supports model types: X2 pro 4, X2 pro 7, X2 pro 7 – 2eth, X2 pro 10, X2pro 12, X2 pro 15, X2 pro 21, X2 marine 7, X2 marine 15. X2 control 4, X2 control 7, X2 control 10, X2 control 12, X2 control 15.
X2 marine 7 SC, X2 marine 7 HB SC, X2 marine 15 SC, X2 marine 15 HB SC.
NOTE! Update of Image requires update of related EBOOT Build 569 as well.
Update EBOOT via “Make Recovery SD Card”, see “Beijer Panel Image manual" (MAEN205x) for information.
- The EBOOT is included when you create "Recovery SD" from the Image Loader.
X2 pro / X2 marine / X2 control - Image V1.4 b581 (Obsolete)
Firmware/image version 1.4 build 581 to X2 pro / X2 marine / X2 control
Click here to download Release notes PIEN344D / Last minute notes PIEN345D.
X2 image 1.0 b325
X2 image 1.0 b325
Released Version | Description |
X2 pro, X2 marine 1.0 B325 | September 2016 Supports model types: X2 pro 4, X2 pro 7, X2 pro 12, X2 pro 15, X2 pro 21. X2 marine; X2 marine 7, X2 marine 15. |
For deteiled overview about known limitations review the X2 Last Minute Notes.
X2 image 1.1 b448 release
X2 image 1.1 b448 release
X2 pro 4, X2 pro 7, X2 pro 10, X2 pro 12, X2 pro 15, X2 pro 21.
X2 marine 7, X2 marine 15.
X2 pro / X2 marine / BoX2 pro, image V2.0 b773 (Obsolete)
Image loader for upgrading X2 pro, X2 marine and BoX2 pro devices to version 2.0. See attached Release notes as well as Last minute notes.
Latest verion is found here:
X2 pro series 2.1 b894 (Current)
https://www.beijerelectronics.com/en/support/Help___online?code=4ABA7F9F-7DCB-4A57-AFDF-1FC752EE50DA
Firmware image for X2 pro, X2 marine and BoX2 pro.
X2 pro / X2 marine / BoX2 pro image V1.5 (Obsolete)
Official release of version 1.5 b686